PROTHERM 20 (30, 40) KLZ
Instructions for Use
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2. Boiler Accessories and Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3. Boiler Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4. Description of Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5. Boiler Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6. Boiler Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
7. Safety of Life and Property . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
8. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9. Complete Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
10. Transportation and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Instructions for Installation
3. Boiler Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4. Description of Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5. Boiler Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6. Boiler Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Technical Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Equithermal regulation of boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
List of Figures
Fig. 1 Basic and Connection Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Fig. 2 Boiler Working Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Fig. 3 Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Fig. 4 Diagram of Control Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Fig. 5 Switch Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Fig. 6 Regulation Elements of Combined Gas Armature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Fig. 7 Electrical Wiring Diagram of PROTHERM 20(30,40) KLZ . . . . . . . . . . . . . . . . . . . . . . . 26
Page view 0
1 2 3 4 5 6 ... 30 31

Summary of Contents

Page 1 - List of Figures

1PROTHERM 20 (30, 40) KLZInstructions for Use1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2 - Definitions

10PROTHERM Instructions for Use 20 (30, 40) KLZThe boiler is put on the floor (or a special base plate). The floor must have at least usual load capac

Page 3 - Dear Customer

11PROTHERM Instructions for Use 20 (30, 40) KLZIn order to really prevent water leaks from the safety valve, the “high-pressure” expansion vessel’s pr

Page 4

12PROTHERM Instructions for Use 20 (30, 40) KLZ4. Description of Controls4.1 Description and Functions of ControlsThe controls and indicators are show

Page 5 - 1. Introduction

13PROTHERM Instructions for Use 20 (30, 40) KLZEmergency thermostat – if the HCW is over-heated, the emergency thermostat will shut down the boiler an

Page 6

14PROTHERM Instructions for Use 20 (30, 40) KLZAll parameters of the boiler are set with the MODE and DOUBLE ARROW buttons and the display. When thebo

Page 7 - 2.2 Boiler Accessories

15PROTHERM Instructions for Use 20 (30, 40) KLZ5. Boiler Operation5.1 Boiler Preparation and StartThe preparation for and commencing of the boiler ope

Page 8

16PROTHERM Instructions for Use 20 (30, 40) KLZ5.4 Breaks in Boiler OperationIf the operation of the boiler is to be stopped for a shorter period of t

Page 9

17PROTHERM Instructions for Use 20 (30, 40) KLZ7. Safety of Life and Property7.1. Technical Requirements for Boilers – Product Compliance and Safety o

Page 10 - 3.2 Boiler Installation

18PROTHERM Service Booklet 20 (30, 40) KLZThe following instructions are for specialised professionals only.Together with the “Instructions for Use” a

Page 11

19PROTHERM Service Booklet 20 (30, 40) KLZtem with cold water, purge it, setting the pressure to the expected final value, as shown by the boiler pres

Page 12 - 4. Description of Controls

2PROTHERM 20 (30, 40) KLZDefinitionsThese Instructions indicate Warning, Caution and Comment to emphasise information or instructions we con-sider imp

Page 13 - » – komfortní teplota OV

20PROTHERM Service Booklet 20 (30, 40) KLZThe setting is changed by pushing the DOUBLE ARROW button, it is confirmed and stored in the memory bythe MO

Page 14

21PROTHERM Service Booklet 20 (30, 40) KLZ5.2. First HeatingThe First Heating is a short-term operation of the boiler after its installation and final

Page 15 - 5. Boiler Operation

22PROTHERM Service Booklet 20 (30, 40) KLZ6. Boiler Maintenance6.1. Professional MaintenanceThe professional preventive maintenance is described in th

Page 16 - 6. Boiler Maintenance

23PROTHERM Service Booklet 20 (30, 40) KLZOnly original parts supplied by the manufacturer or a party authorised by the manufacturer maybe used for th

Page 17 - 8. Warranty

24PROTHERM 20 (30, 40) KLZ

Page 18 - 3. Boiler Assembly

25PROTHERM 20 (30, 40) KLZTechnical ParametersType Unit 20 KLZ 30 KLZ 40 KLZCategory II2H3PDesign B11BSIgnition el. sparkFuel / input pressure natural

Page 19

26PROTHERM 20 (30, 40) KLZFig. 7 Electric Wiring Diagram of PROTHERM 20 (30, 40) KLZ

Page 20 - 9” maximum starting power

27PROTHERM 20 (30, 40) KLZEquithermal RegulationWhen starting the boiler and adjusting the heating modes, i.e., the parameters of the regulation (sele

Page 21 - 5.2. First Heating

28PROTHERM 20 (30, 40) KLZ

Page 22

29PROTHERM 20 (30, 40) KLZ

Page 23

3PROTHERM 20 (30, 40) KLZDear Customer,You have become an owner of a cast-iron PROTHERM KLZ boiler, for natural gas or LPG. We believe it willserve yo

Page 25 - Technical Parameters

PROTHERM s.r.o., 252 19 Chrášťany 188, Praha - západtel.: (02) 57 95 09 19; fax: (02) 57 95 09 17Instructions for Use and Installationof Cast-Iron Bo

Page 26

4PROTHERM Instructions for Use 20 (30, 40) KLZTYPE a b ∅ d20 327,5 191 13030 285 106 13040 242,5 21 150Fig. 1 Basic and Connection DimensionsA – DHW i

Page 27 - Equithermal Regulation

5PROTHERM Instructions for Use 20 (30, 40) KLZ1. IntroductionCast-iron gas-combusting boilers for installation on the floor (especially in cellars of

Page 28

6PROTHERM Instructions for Use 20 (30, 40) KLZ 1. – Control panel 2. – POLO-TURBO extension 3. – Chimney flange 4. – Automatic purging valve 5. –

Page 29

7PROTHERM Instructions for Use 20 (30, 40) KLZOther important features of these boilers are:• Continuous regulation, based on ongoing comparison betwe

Page 30

8PROTHERM Instructions for Use 20 (30, 40) KLZHydraulic construction is a system of pipes with two pumps, backward flap valves and safety elements, i.

Page 31